One of India’s most industrialised states, Gujarat, has come up with a plan. The state has amended its fire safety regulations to address the problem. To safeguard its industrial units, it has classified them into three fire hazard categories. The new risk-based fire safety regulatory framework shifts the focus beyond building height and structural characteristics to the actual use, occupancy, and associated fire hazards of buildings. The state has introduced 258 fire safety checklists for different types of buildings. One of the most significant features is the separate category for industrial buildings, which will also include IT parks and data centres. Manufacturing plants, power plants, food processing units, refineries and other industrial establishments have varying levels of fire risks. Recognising this, industrial units have been classified into three hazard categories. Categories For Industrial Units Under the revised Gujarat Fire Safety Regulations, industrial buildings have been given a distinct identity under Group G. This is a significant change, as manufacturing processes, raw materials, combustible substances, and the likelihood of fire vary across different industries. Three Industrial Hazard Categories G-I – Low Hazard: Industrial units where the manufacturing process and materials involved present a relatively low likelihood of rapid fire spread. G-II – Moderate Hazard: Industrial units where manufacturing processes or stored materials may result in moderate fire spread and considerable smoke generation. G-III – High Hazard: Industrial units where there is a possibility of rapid fire spread, toxic smoke generation, or explosions. New Certification Timeline The revised provisions for industrial buildings will come into effect from 1 April 2027. Under the new Third Schedule, Fire Safety Compliance Certificates will be required for industrial buildings with a built-up area exceeding 500 square metres in the Low and Moderate Hazard categories and exceeding 50 square metres in the High Hazard category. A notable aspect of this classification is that modern infrastructure such as IT parks and data centres have been included under Business Buildings. Shopping malls, cinemas, and public gathering venues fall under the Assembly category, while buildings with mixed usage have been assigned a separate Group K classification. Eliminating Duplication The amendments also seek to improve consistency between fire safety regulations and building construction provisions. Greater clarity has been introduced in the technical references connecting the Gujarat Development Control Regulations (GDCR), Fire Safety Regulations and the National Building Code (NBC). Under the revised Rule 22, the minimum standards prescribed under the GDCR or Fire Safety Regulations will apply to the following safety arrangements in buildings: Access roads for fire tenders. Number, width and arrangements of emergency exits. Fire-check doors and exit protection. Compartmentation and smoke management. Fire extinguishers and hose reels. Automatic fire detection and alarm systems. Automatic sprinkler and hydrant systems. Fire pumps and water storage for firefighting. Emergency lighting, exit signage and standby power. Refuge areas and fire control rooms. Fire Safety Compliance High-rise buildings: Generally, buildings with a height of 15 metres or more, subject to specified exemptions. Hotels, Business, Mercantile, Storage, Hazardous and Mixed Occupancy Buildings: Buildings where the total built-up area of one or more floors exceeds 500 square metres. Educational and Institutional Buildings: Buildings with a height of 9 metres or more. Other Mandatory Categories include all assembly buildings, all multi-level parking facilities, incidental assembly occupancy exceeding 300 square metres on any floor, buildings having two or more basements, or a single basement exceeding 500 square metres, and all fuelling stations. Do’s For Building Owners In view of the revised regulations, the following steps will be important for stakeholders: Identify the appropriate occupancy category of the building. Industrial units must assess their G-I, G-II, or G-III Hazard Classification. Review the applicable checklist from the 258 prescribed checklists. Inspect fire alarms, sprinklers, hydrants, pumps, and water storage arrangements. Ensure the availability of emergency exits and access for fire tenders. Conduct regular mock fire drills and inspections. Comply with the applicable provisions for fire safety certificates and their renewals.